CHARM II Tetracycline Tests Print E-mail
Recommended Screening / Detection Levels

Tetracyclines

Tissue1

ppb

Egg1

ppb

Urine2

ppb

Serum3

ppb

Feed4

ppb

Grain5

ppb

Honey5

ppb

Milk6

ppb

Tetracycline

20

20

600

40

100

100

4

4

Chlortetracycline

100

100

3000

200

800

800

20

28

Oxytetracycline

100

100

3000

200

800

800

20

19

Demeclocycine

UD

UD

UD

UD

UD

UD

UD

30

Doxycycline

UD

UD

UD

UD

UD

UD

UD

30

Methacycline

UD

UD

UD

UD

UD

UD

UD

30

Minocycline

UD

UD

UD

UD

UD

UD

UD

600

Rolitetracycline

UD

UD

UD

UD

UD

UD

UD

10

UD = Un-determined
ND = Procedure not developed

NOTES:

  1. Preparation dilution 1 part sample to 3 parts buffer. Alternative control point procedure may be used to enhance sensitivity 2 fold.
  2. Dilution range 1 part sample to 100-150 parts buffer to predict tissue action levels. Minimal allowable dilution 1:4 will enhance sensitivity 25 fold.
  3. Dilution 1 part sample to 20 parts buffer to predict tissue action levels. Minimal allowable dilution 1:4 will enhance sensitivity 5 fold.
  4. Dilution 1 part sample into 2 parts extract, 1 part extract to 25 parts buffer.
  5. Dilution 1 part to 4 parts for beta-lactams, macrolides, streptomycins; 1 part to 10 parts for Sulfa Drugs and Tetracyclines; and 1part to 20 parts for Amphenicols.
  6. Sensitivities listed are testing milk undiluted. For US safe levels a dilution of 1 part to 9 parts is recommended to screen at 300ppb total tetracyclines.
 
CHARM II System
Charm II System


Run Tests with CHARM II System

The Charm II System has become the standard used by industry and regulatory agencies for domestic monitoring and international trade.